We specialize in the production of funeral equipment, cremation machines, cremation furnaces, ice coffins, corpse refrigerators, and body handling equipment. Welcome to consult and customize!
Funeral equipment company manufacturer's phone number

current location:homepage > > Funeral equipment > Cremation equipment

Specifications, parameters, and requirements for flatbed crematoriums in funeral homes and crematoriums

Belonging category:Cremation equipment Publishing Date:20250418 views:36

Specification, parameters and requirements of flat cremation machine in funeral parlour crematorium


(1) External dimensions of the furnace body: length× width× height =3400×2200×3200mm.


(2) Size of bi-directional corpse-entering vehicle: 3700× 880× 800 mm.


(3) Working temperature of main combustion chamber: 700℃~900℃ (automatic energy-saving and environment-friendly burner should be installed in the main combustion chamber. )


(4) Working temperature of secondary combustion chamber: 600℃~800℃


(5) Surface temperature of cremator: ≤40℃


(6) Thermal insulation performance: the combustion chamber temperature is 900℃, and after 24 hours of shutdown, it is ≥300℃.


(7) Furnace pressure: -100Pa~-160Pa within 3 minutes after entering the corpse, and -5Pa~-40Pa after entering the corpse for 3 minutes. The fan doesn't work, the burner doesn't work, and the furnace temperature is -4Pa~-2Pa.


(8) Air oxygen temperature: ≥300℃ when using hot air for oxygen supply; When using cold air for oxygen supply: the same temperature as room temperature.


(9) Blower power: 7.5kw high-pressure blower, wind pressure: 10000~12000Pa.


(10) Power of induced draft fan: 7.5kw normal pressure fan, wind pressure: 2000~2500Pa.


(11) Burner: well-known brand.


(12) Fuel grade: -10#~20# light diesel oil.


(13) Fuel consumption of single incinerator: < 12kg/ incinerator (cold furnace).


(14) Fuel consumption of continuous incineration: < 8kg/ appliance (hot furnace).


(15) Incineration time of single utensil: < 50 minutes/utensil (cold furnace).


(16) Continuous incineration time: < 40 minutes/appliance (hot furnace).


(17) Smoke exhaust mode: upper smoke exhaust duct (stainless steel) Venturi low chimney ejects and discharges.


(18) Overhaul cycle: ≥ 3,000 sets/furnace.


(19) Total power: ≥20kw.


(20) Control mode: Low-voltage electrical appliances are equivalent to well-known foreign products, the lower computer is a high-end programmable controller, and it has three sets of operating systems: color display, digital display touch button/strong current/manual, which can be switched at will without interference. The furnace is equipped with a probe monitoring device, which can be used for real-time monitoring, automatic feedback and automatic instruction during the whole incineration process.