Belonging category:Cremation equipment Publishing Date:20250418 views:33
Technical requirements, specification parameters and operation standards of relic incinerator in funeral parlour
1. The external dimension of the furnace body is L×W×H=8770×3770×3300mm.
2. The size of the feeder car is L× W× H = 3400× 2670× 2400 mm.
3 working power supply 380V-50Hz
4 dust removal fan power 18.5kw
5 The flue gas treatment capacity is 13,000m3/h.
6 blower power 7.5kw
7 automatic loading power 1.5kw
8 Dust removal method: eddy current sedimentation and bag dust removal.
9 Dust removal efficiency is 98%
10 continuous working mode
11 Incineration speed is 150-200kg/h.
12 Furnace volume is 7.63m3.
13. the size of the slag collecting tank is L×W×H=3000×3000×4000mm.
14 air compressor power 7.5kw
15 slag removal speed is 0.2m/s.
16 Control modes are manual and automatic.
17. It is controlled by programmed touch-type micro-touch switch.
18 service life of more than 10 years.
19 The total weight of furnace body is 24T.
20 Tail gas temperature ≦60℃
21 ignition mode electronic ignition
23 Furnace pressure-10-5pa
24 Furnace fire resistance 600-800℃