Belonging category:Cremation equipment Publishing Date:20250418 views:32
Technical requirements of luxury ash-picking cremator, technical specifications, dimensions and technical performance requirements of luxury cremator:
1 The external dimension of the furnace body is L× W× H = 6900× 2560× 3440mm (5%).
Overall dimensions of 2 trolleys are l× w× h = 2100× 700× 785 mm (5%).
3 furnace size l× w× h = 2450× 660× 535 mm (5%)
The average fuel consumption of single cremation is 8-15 liters/set; 15-20 cubic meters of natural gas
5. The average fuel consumption for continuous cremation is 7-12 liters/set; 12-15 cubic meters of natural gas
6 Use fuel 0-35# light diesel oil or natural gas.
7 Single cremation time ≦55 minutes/set
8 The average time for continuous cremation is 35 ~ 50 minutes/set.
9 The working temperature of the main combustion chamber is 850-950℃
10 The working temperature of the reburning chamber is 600-900℃
11. The external temperature of cremator is below 20℃, and local temperature is below 50℃.
12 Thermal insulation performance The temperature of the main combustion chamber is 900℃, and after 24 hours of shutdown, the temperature is higher than 400℃.
13 main furnace working pressure-5 ~ -5~-20Pa
14 refractories, new special high-temperature resistant composite materials and high-alumina refractory bricks
15 Furnace structural materials: super-grade refractory bricks and new high-strength cement.
16 thermal insulation material polymer high temperature insulation material
17 decoration material Q235-A high quality steel
18 Main Burner High Efficiency, Environmental Protection and Energy Saving Burner
19 Auxiliary Burners Efficient, Environmental Protection and Energy Saving Burners
20 induced draft fan power: 7.5 Kw air volume: 5512-10562 m3/h wind pressure: 2554-1673 Pa.
21 blower power: 7.5 Kw air volume: 1100 m3/h
Wind pressure: 13000Pa
The cooling room adopts an axial fan with power of 2.2kw, and the air-conditioning compressor is used as the refrigeration source to generate cold air, which is quickly cooled through the pipeline.
Mechanical lifting adopts national standard steel, and the motor operation is automatically controlled by the screw elevator, which plays the role of pit surface lifting.
The mechanical transmission part adopts high-quality steel, wpa series worm gear reducer and full chain transmission.
25 pit face exchange double pit face, translation type.
26 pit surface replacement cycle is 1 year.
27 The dead weight of pit body is 14t.
28 service life of 10 years or 5000 sets.
29 overhaul cycle more than 5000 bodies.
The environmental protection effect meets the national environmental protection requirements, meets the requirements of GB13801-2015, and meets the requirements of national first-class funeral parlours.
31 Smoke exhaust mode: either upper smoke exhaust or lower smoke exhaust can be used.
32 smoke blackness value When the normal remains are ignited, the smoke blackness value is not greater than the first level in Lingemann.
The double-bed corpse transmission system has mechanical transmission, a corpse receiving position, a cooling position and a burning position, and the corpse beds work in turn.
34 corpse-feeding system-fixed conveying corpse-feeding trolley
35 oil supply system measures oil consumption and oil pipeline
36 energy storage system uses high temperature resistant industrial steel as energy storage device, and the heat energy utilization reaches 80%.
The automatic control system adopts 15-inch industrial master LCD screen and PLC programming, computer touch automatic control, and has standard communication port, which can realize high-end functions such as automatic ignition, automatic pressure regulation and automatic control of furnace temperature to make the remains burn in the best state. Automatic and manual control systems.
38 TV monitoring system includes chimney exhaust monitoring and corpse entry system monitoring, using 21-inch industrial-grade display and high-definition probe. It is convenient to master the smoke exhaust state, and the smoke emission concentration can be adjusted manually or automatically at any time.
Electrical components of electrical control system Low-voltage electrical components, pressure modules and temperature modules automatically detect furnace pressure and temperature.
Electrical control series and short circuit have automatic protection function and system comprehensive control function.
The total power of electrical appliances is less than 27kw.
The working voltage of the system is AC 380V 50Hz.
Control the working voltage of AC 220V and DC 24V.