Belonging category:Funeral refrigeration Publishing Date:20250418 views:34
Technical requirements for the remains freezer and three-door integrated freezer in funeral parlour:
1. Size requirements: the external size is L2200×W920×H2140(mm), and the specification size can be 5% of the required size.
2. Material: external material 304 stainless steel; Internal material embossed aluminum plate is not less than 0.6 mm.
3. Rated temperature: not higher than-18C°.
4. Product features: fully automatic rotating double-set system.
5. Unit form: totally enclosed imported compressor.
6. Refrigerant: R404A.
7. Power supply: 220V,50HZ.
8. Condenser: air-cooled fin copper coil.
9. Evaporator: directly cooled copper coil.
Insulation layer: Polyurethane foam with overall high-pressure temperature recovery (thickness 100㎜) with a density of over 48kg/m3.